首 页网站地图RSS订阅高级搜索保留
生物实验网
设为首页
加入收藏
站长信箱
主页|bio资讯 |DNA实验 |PCR实验 |RNA实验 |蛋白实验 |基本实验技术 |生化与免疫技术 |生物信息学 |细胞生物学 |杂交实验 |学科相关 |交叉领域 |
当前位置: 主页>基本实验技术>动植物实验> 查看文章详细内容
站内资料搜索
热门关键字: dna  EST  r DNA  pcr  抗体  rt pcr  t dna  tail pcr  PCR sscp  cDNA

相关文章
>胚胎植入前TUNEL检测-TUNE
>Differential Staining of
>ARNT Knockout genotyping
>FAM caspase 8 and 9 bind
>ARNT transgenic genotypi
>将滋养层和内细胞群分别染
>Ahr knockout genotyping
>Bovine Rectal Palpation
>Ahr transgenic genotypin
>鼠尾制备胶原蛋白-Making
热点文章
UPDATED DIRECTIONS FOR N
PEAS Labeling Gcn4-cys
Yeast Nuclear Extract (S
In vitro transcription w
Polymerase III in vitro
ISOLATION OF HIGH MOLECU
RNA Isolation from Yeast
Pulsed Field Gel Electro
CHROMATIN IMMUNOPRECIPIT
CHIP PROTOCOL FOR YEAST
调节培养板的气体环境
[ 文章来源: | 文章作者: | 发布时间:2007-01-24|  字体: [ ]  
Mini-Chamber for regulating gaseous environment during culture 一个简单又省钱的方法来调节培养板的气体环境
 
A simple and inexpensive chamber for regulating gaseous environment of small culture plates, such as those used for culture of preimplantation embryos, can be constructed using disposable media-filtration devises such as Corning’s 115-ml system.  The following is a description of how to make such a device.
 

1. The basic unit is constructed from a media filtration unit such as Corning’s 115 ml filter system (catalog numbers 430944-430947).

2. Tygon tubing (3.2 mm i.d. x 6.4 mm o.d.) with a stopcock fastened to the end is attached to the hose connector.

3.  A 00 size rubber stopper is inserted into the pour spout of the filter system.

4. The membrane in the filter system is punctured in several places to facilitate movement of gases.

5. Culture plates (up to a 60 mm petri dish plate) are gently positioned on top of the membrane. If the plate is large, it is difficult to maneuver the plate into the chamber with fingers.  In this case, a cradle underneath the plate can be constructed with tape to facilitate placement of the dish.

6. The lid of the filter system is taped securely with scotch tape and parafilm is placed around the lid to make the chamber airtight.

7. Gases are injected for 3 min through the pour spout from a hose connected to the gas cylinder while the stopcock was in the open position.

8. After injection of gases is completed, the rubber stopper is fastened to the pour spout and the stopcock is moved to the closed position.

9. To prevent contamination during injection of gases, a filter (0.22 mm) is attached to the gas hose.