| Troubleshooting Guide: Western Blot
|
| [ 文章来源: | 文章作者:
| 发布时间:2006-09-27|
字体:
[大
中
小]
| |
|
Troubleshooting Guide: Western Blot
Problem: Poor Transfer
| Possible Source |
Test or Action |
| Membrane does not wet uniformly |
Pre-wet membrane in 100% methanol |
| MW of protein is less than 10,000 |
If protein has MW <10,000, it may have 揵lown through?the membrane. Reduce transfer time, or place two sheets of transfer membrane soaked in Anode Buffer II under gel in transfer stack, or select membrane with smaller pore size |
| Isoelectric point of protein is <9 |
Use alternate buffer system (such as CAPS buffer pH 10.5) with a higher pH
Assemble transfer stack with additional membrane soaked in cathode buffer on the cathode side of gel. This will capture proteins that migrate towards the cathode. Identify membrane location in stack and immunostain all membranes in stack |
| Methanol concentration |
Higher methanol concentration increases binding to membrane but may retard transfer from gel |
| SDS concentration |
Adding 0.005 - 0.01% SDS to cathode buffer can increase transfer efficiency of protein from gel Note: Increased SDS concentration may interfere with binding to membrane |
| Thick gel |
Thicker gels or higher MW proteins may require longer transfer times |
Problem: High Background Staining
| Possible Source |
Test or Action |
| Membrane does not wet uniformly |
Pre-wet membrane in 100% methanol |
| Inadequate blocking |
Optimize the blocking step by trying alternate blocking solutions (e.g., non-fat milk, gelatin, etc.) or increasing time and temperature of blocking step |
| Cross-reactivity of antibody reagents |
Check for cross-reactivity of antibody reagents to the blocking protein |
Problem: Low Protein Binding
| Possible Source |
Test or Action |
| Overwashing |
Keep the length of TTBS washes to a minimum
See 揚oor Transfer?problem for alternatives |
Problem: High Protein Binding, Low Signal
| Possible Source |
Test or Action |
| Inadequate antibody staining |
Check antibody dilutions and expiration dates |
| Inactive AP conjugate and/or substrate |
Add enzyme conjugate to substrate reagents as prepared in step 7 of immunostaining procedure. If color occurs, reagents are performing properly |
| Poor sample |
If positive control worked, sample may not contain protein of interest or it may be present at concentrations too low to detect |
Problem: Several Bands are Stained
| Possible Source |
Test or Action |
| Non-specific binding of secondary reagents |
Check non-specific binding by running extra sample lane and omitting 1?antibody from immunostaining procedure, run with a non-specific antibody control in place of 1?antibody, or perform dot blot and omit the 1?antibody. If staining occurs, choose an alternate 2?antibody |
| Primary antibody is not monospecific |
Use a monoclonal or affinity purified antibody |
上一篇:分子杂交技术(一) 下一篇:Western Immunoblotting of Proteins
|
|
|