I think lower concentrations should work accurately. I've done quantitative assays RNA inputs for RT's as low as 15ng/sample. That was diluted 1:10 and used at a final concnetration of 0.27ng of RT in the QPCR rxn. I think it also depends on your detection equipment. The ABI 7900 is quite sensitive. I'm not familiar with the lightcycler.
I think lower concentrations should work accurately. I've done quantitative assays
RNA inputs for RT's as low as 15ng/sample. That was diluted 1:10 and used at a final concnetration of 0.27ng of RT in the QPCR rxn. I think it also depends on your detection equipment. The ABI 7900 is quite sensitive. I'm not familiar with the lightcycler.
I use 10 ng cDNA per qPCR reaction with good results. Have you tried making serial dilutions of your cDNA to determine your quantiative range? I have found that I can get acceptable Ct values down to .01 ng cDNA.